Man-Machine Interface (MMI) Error Code Registry
Showing 4 Core WSPS Diagnostics
Display Code on MMI Event Name Affected Axle Cause of Event Instruction to Railway Actions
0101 Internal board error on Main Board MB04B Axles 1 - 4
  • 7401
  • S301
  • main Board MB04B-A1 defect
change Main Board MB04B-A1
0202 Internal board error on Extension Board EB01A Axles 1 - 4
  • Extension Board EB01A-A2 defect
  • check the single messages
  • change Extension Board EB01A-A2
  • check if the WSP can be powered on after standby
1001 Time-out at dump valve of axle 1 Axle 1
  • extremely low adhesion coefficient between track and wheels causing dump valve to pull out of operation
  • Main Board MB04B-A1 defect
delete message by using the MMI and start the test run; if the message occurs again change Main Board MB04B-A1 and install the software afterward
1101 Short/Open circuit at frequency input of Main Board MB04B-A1 for speed sensor signal detection on axle 1 Axle 1
  • cable break to speed sensor
  • short circuit of speed sensor
  • plugs from Main Board MB04B-A1 to speed sensor unfastened
check cable connection, plugs and sensor resistance; clean or replace speed sensor assembly
Showing 1 to 4 of 42 error codes