| SL. | Date | Train No. | Type & Coach No. | OEM Make | Inventory Issue / Fault & Error Code | Actual Issue | Action Taken | Status | Auditor |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 23.06.2026 | 12002 SHATABDI EXP |
TYPE LHB AC 3T COACH CR-223456 |
Faiveley Transport |
Main Board MB04B-A1 Defect Internal board error ERROR: 0101 |
Verify board seating, clean input contacts, or replace Main Board MB04B-A1 | Replaced Main Board MB04B-A1 with spare from inventory depot | RESOLVED |
akhil golu
SCH #WO-10101 20.06.2026 |
| 2 | 15.06.2026 | 12952 RAJDHANI EXP |
TYPE LHB AC 2T COACH WR-193425 |
Knorr-Bremse |
Solenoid dump valve timeout Axle 1 response failure ERROR: 1001 |
Start pneumatic self-test, verify track adhesion coefficient, clean dump valve assembly | Executed pneumatic self-test, cleared dump valve nozzle blockage | RESOLVED |
akhil golu
SCH #WO-10102 13.06.2026 |
| 3 | 15.06.2026 | 12056 JAN SHATABDI |
TYPE LHB GEN COACH NR-142211 |
Medha Servo |
Extension Board EB01A-A2 Fault Internal board error ERROR: 0202 |
Check standby power lines, inspect EB01A-A2 card components, change board if necessary | Awaiting spare Extension Board EB01A-A2 from division depot | PENDING |
akhil golu
SCH #WO-10103 13.06.2026 |
| 4 | 14.06.2026 | 12260 DURONTO EXP |
TYPE LHB AC 3T COACH ER-202115 |
Escorts Ltd |
Speed Sensor Open/Short circuit Axle 1 signal drop detection ERROR: 1101 |
Check sensor plug connection, measure coil resistance (800-1200 ohms), replace speed sensor | Cleaned speed sensor connector contacts and refastened plug | RESOLVED |
akhil golu
SCH #WO-10104 13.06.2026 |